Assembly Instruction
KS2 / KS2 T
WIN
I
NSTALLATION
STEP
5:
H
OLE
LAYOUT
FOR
FRAME
AND
CASEMENT
BRACKETS
05
Solo application KS2 xxx / Version: right
230V
Pressure load - Frame assembly
(Top-hung - outward opening windows)
24V
230V
Minimum overall height of casement
(FAH)
Stroke
200
300
400
500
Height
350
400
450
600
Frame bracket:
Casement bracket:
Drive:
Space on the frame: 22 mm
K94
F21
fi xed
Stroke 200 Stroke 300 Stroke 400 Stroke 500
A
476
521
571
686
B
490
535
585
700
C
170,5
215,5
265,5
380,5
X
≥ 570
≥ 570
≥ 570
≥ 800
Y
≥ 475
≥ 520
≥ 570
≥ 685
(Top-hung - outward opening windows)
K94
A
M5x10
DIN 7500
F21
K94 = 24
K94
AK
1/2 FAB
F21
RA
FL
B
C
A
X
Y
= Symmetrical /
= Asymmetrical
FAB min.:
When mounting two drives (tandem operation),
a minimum distance of 50 mm between the drives
is considered.
Window versions:
Version left (L):
as right (R), but in mirror image
Bottom hung - outward opening
Top hung - outward opening
Side-hung - outward opening
Horizontally pivoting casement
Projecting top-hung
casement
Version: left