- 106 -
Climatic exposure
open air
open air
Status of neutral (TT or NT)
earthed
earthed
Status of neutral (IT) (optional)
insulated
insulated
Engine 4)
Standard
ISO 3046
ISO 3046
ISO 8528-2
ISO 8528-2
Type PERKINS
1104C-44TG3/TG2
1104C-44TG3/TG2
Rated net output
54 kW
60 kW
rating type acc. ISO 3046-7
ICXN
ICXN
Coolant
coolant
coolant
Combustion system
direct injection
direct injection
Aspiration
turbo charged
turbo charged
Number of cylinders
4
4
Swept volume
4.41 l
4.41 l
Speed governing
mechanical / electronic
mechanical / electronic
Governor type (optional)
electronic with TG2
electronic with TG2
Capacity of oil sump (initial fill)
8.5 l
8.5 l
Capacity of cooling system
12.6 l
12.6 l
Electrical system
12 Vdc
12 Vdc
Emission compliance
EU stage II
EU stage II
Maximum premissible load factor of PRP during 24h period
80%
80%
Alternator 4)
Standard
IEC34-1
IEC34-1
ISO 8528-3
ISO 8528-3
Make
Leroy Somer
Leroy Somer
Model
LSA43.2 M45
LSA43.2 M45
Rated output, class H temperature rise
60 kVA
71 kVA
rating type acc. ISO 8528-3
BR 125/40°C
BR 125/40°C
Degree of protection (IP index acc. NF EN 60-529)
IP 23
IP 23
Insulation stator class
H
H
Insulation rotor class
H
H
Number of wires
12
12
Содержание QAS 60 Pd
Страница 1: ...QAS 60 Pd S2A APP Instruction Manual for AC Generators English...
Страница 2: ......
Страница 88: ...88 6 4 2 3 Solving alarms Menu flow Qc4002 Qc4002 Qc4002 OR Qc4002 G OK LOG SOLVE PROBLEM See page 86...
Страница 111: ...111 Circuit diagrams...
Страница 115: ...115...
Страница 119: ...119...
Страница 128: ...128...
Страница 132: ...132...
Страница 139: ...139...
Страница 141: ......
Страница 142: ...Printed in Belgium 04 2012 2954 6280 00 www atlascopco com...