9.3.5
Outlet sockets (S) - Set 2
A brief description of all outlet sockets and circuit
breakers provided on the generator is given hereafter:
X2 ....... 1-phase outlet socket (230 V AC)
Provides phase L3, neutral and earthing.
X3 ....... 3-phase outlet socket (400 V AC)
Provides phases L1, L2 and L3, neutral and
earthing.
X4 ....... 3-phase outlet socket (400 V AC)
Provides phases L1, L2 and L3, neutral and
earthing.
X5 ....... 3-phase outlet socket (400 V AC)
Provides phases L1, L2 and L3, neutral and
earthing.
X6 ....... 3-phase outlet socket (400 V AC)
Provides phases L1, L2 and L3, neutral and
earthing.
Q2 ....... Circuit breaker for X2
Interrupts the power supply to X2 when a
short-circuit occurs at the load side, or when
the overcurrent protection (16 A) is
activated. When activated, Q2 interrupts
phase L3 and the neutral towards X2. It can
be activated again after eliminating the
problem.
Q3 ....... Circuit breaker for X3
Interrupts the power supply to X3 when a
short-circuit occurs at the load side, or when
the overcurrent protection (63 A) is
activated. When activated, Q3 interrupts the
three phases towards X3. It can be activated
again after eliminating the problem.
Q4 ....... Circuit breaker for X4
Interrupts the power supply to X4 when a
short-circuit occurs at the load side, or when
the overcurrent protection (63 A) is
activated. When activated, Q4 interrupts the
three phases towards X4. It can be activated
again after eliminating the problem.
Q5 .......Circuit breaker for X5
Interrupts the power supply to X5 when a
short-circuit occurs at the load side, or when
the overcurrent protection (32 A) is
activated. When activated, Q5 interrupts the
three phases towards X5. It can be activated
again after eliminating the problem.
Q6 .......Circuit breaker for X6
Interrupts the power supply to X6 when a
short-circuit occurs at the load side, or when
the overcurrent protection (16 A) is
activated. When activated, Q6 interrupts the
three phases towards X6. It can be activated
again after eliminating the problem.
Q1
Q2
Q6
Q5
Q4
Q3
X5
X6
X4
X3
X2
Circuit breaker Q1 does not only
interrupt the power supply towards
X1, but also towards X2, X3, X4, X5
and X6.
Make sure to switch on circuit
breakers Q1, Q2, Q3, Q4, Q5 and Q6
after starting the generator when
power supply is done by means of
X2, X3, X4, X5 or X6.
!
Содержание QAS 60 Pd
Страница 1: ...QAS 60 Pd S2A APP Instruction Manual for AC Generators English...
Страница 2: ......
Страница 88: ...88 6 4 2 3 Solving alarms Menu flow Qc4002 Qc4002 Qc4002 OR Qc4002 G OK LOG SOLVE PROBLEM See page 86...
Страница 111: ...111 Circuit diagrams...
Страница 115: ...115...
Страница 119: ...119...
Страница 128: ...128...
Страница 132: ...132...
Страница 139: ...139...
Страница 141: ......
Страница 142: ...Printed in Belgium 04 2012 2954 6280 00 www atlascopco com...