Qc4002™ MkII module
The Qc4002™ MkII module is located inside the
control panel, and communicates with a display unit,
located in front of the control panel. This control
module will carry out all necessary tasks to control
and protect a generator, regardless of the use of the
generator.
This means that the Qc4002™ MkII module can be
used for several applications.
2.4.2
Output terminal board
The cubicle provides a terminal board for easier
connection of cables. It is situated below the control
and indicator panel.
S2........Emergency stop button
Push the button to stop the generator in case
of an emergency. When the button is
pressed, it must be unlocked, by turning it
anti-clockwise, before the generator can be
restarted. The emergency stop button can be
secured in the locked position with the key,
to avoid unauthorized use.
Q1 .......Main circuit breaker
Interrupts the power supply to X1 when a
short-circuit occurs at the load side, or when
the earth leak detector (30 mA) or the
overcurrent protection (100 A) is activated
or when the shunt trip is energized. It must
be reset manually after eliminating the
problem.
X1 .......Main power supply (400 V AC)
Terminals L1, L2, L3, N (= neutral) and PE
(= earthing), hidden behind the control panel
door and behind a small transparent door.
w
w
w.
at
la
s
co
pc
o.
co
m
Qc4002
G
!
OK
LO
G
X1
Q1
S2
Содержание QAS 60 Pd
Страница 1: ...QAS 60 Pd S2A APP Instruction Manual for AC Generators English...
Страница 2: ......
Страница 88: ...88 6 4 2 3 Solving alarms Menu flow Qc4002 Qc4002 Qc4002 OR Qc4002 G OK LOG SOLVE PROBLEM See page 86...
Страница 111: ...111 Circuit diagrams...
Страница 115: ...115...
Страница 119: ...119...
Страница 128: ...128...
Страница 132: ...132...
Страница 139: ...139...
Страница 141: ......
Страница 142: ...Printed in Belgium 04 2012 2954 6280 00 www atlascopco com...