1 Presentation of the equipment
1 .1 Packaging
• 1 box: Outdoor unit.
• 1 box: Hydraulic module with NOx low burner and
outdoor temperature probe.
Pairing table
1 .4
Definitions
-Split
: the heat pump is composed of two parts (an
outdoor unit to be located outdoors and a Hydraulic
module to be installed inside the home).
-
Air/water: the outdoor air is the energy source .
This energy is transmitted to the heating water by the
heat pump
-
Inverter: the fan and compressor speeds are modulated
to suit the heat requirements. This technology
economises energy and permits operation with single
phase power supply, regardless of the power rating
of the heat pump, by avoiding high current demands
when started.
-COP
(coefficient of performance: this is the ratio
between the energy transferred to the heating circuit
and the electrical energy consumed.
-
hybrid: the Hydraulic module operates with dual energy
(air/water heat pump and integrated oil boiler).
-
low NOx: Burner designed to minimise the emission
of Nitrogen oxides NOx in the fumes. Generally low
NOx burners are considered to be burners whose
emission rate is below the most severe regulations at
that time. This limit chnages regularly according to the
regulations and technical progress.
Denomination : alféa hybrid duo oil low NOx flue model
11
14 +
11 3 ph .
14 3 ph .
16 3 ph .
Nominal heating performances
(Outdoor T° / initial T°) -
Heating power
+7 °C/+35°C - under-floor heating
kW
10 30
13 50
10 60
13 25
14 89
-7 °C/+35°C - under-floor heating
kW
10 10
11 22
9 75
13 00
13 50
+7 °C/+45°C - LT radiators
kW
9 05
11 32
10 10
12 60
13 00
-7 °C/+45°C - LT radiators
kW
8 33
10 41
8 66
12 50
13 00
Nominal heating performances
(Outdoor T° / initial T°) -
Absorbed power
+7 °C/+35°C - under-floor heating
kW
2 57
3 50
2 68
3 20
3 70
-7 °C/+35°C - under-floor heating
kW
3 94
4 68
3 69
5 18
5 40
+7 °C/+45°C - LT radiators
kW
2 82
3 69
3 01
3 81
4 00
-7 °C/+45°C - LT radiators
kW
4 05
5 24
4 04
6 00
6 37
Coefficient of performance (COP) (+7 °C / + 35 °C)
4.00
3 .86
3 .95
4 .14
4.02
1 .2 Optional equipment
•
2
nd
circuit kit
(ref. 073953).
- to connect 2 heating circuits.
•
Ambient probe T55
(ref. 073951) or
Ambient probe radio T58
(ref. 075313).
- to correct the ambient temperature.
•
Central ambient unit T75
(ref. 073954) or
Central radio ambient unit T78
(ref. 074061).
- to correct the ambient temperature
and programme the PAC
• Anti-vibration pins (ref. 523574).
• Floor s
upport in white PVC
(ref. 809532).
•
Duo pool kit
(ref. 074064).
• High flow
circulator kit
(ref. 073959).
- for a 1 circuit heated floor installation
with a PAC model 13 and 16.
1 .3 Scope
This heat pump permits:
- heating in winter,
- the production of sanitary hot water,
- controlling two heating circuits *,
- heating the pool*.
*: These options require the use of additional kits
(see § "optional equipment").
1 .5 General characteristics
Installation and operating manual
"
1605 - EN
"
alfea hybrid duo heat pump oil low NOx CH
- 4 -
Heat pump
Outdoor unit
Hybrid duo hydraulic module
Model
ref. export
ref
Code
ref
Code
alféa hybrid duo 11 single phase
522 694
WOYG112LCT
700117
MH-HD
024208
alféa hybrid duo 14
+
single phase
522 695
WOYG140LCT
700142
alféa hybrid duo 11 three phase
522 696
WOYK112LCT
700118
alféa hybrid duo 14 three phase
522 697
WOYK140LCT
700143
alféa hybrid duo 16 three phase
522 698
WOYK160LCT
700163