2 Installation
2 .1 Statutory conditions
for installation and servicing
The appliance must be installed and the maintained
by an approved professional in accordance with the
prevailing regulations and code of practice, in particular:
-
The legislation on the handling of refrigerants:
-
Heating installation with floor heating system.
carrying out water floor heating systems.
-
Low voltage electrical installations - Rules.
-
Central heating installations for buildings.
-
Sanitary plumbing for homes.
-
Calculations for sanitary plumbing installations and
evacuation of rain water.
-
Copper pipes. Distribution of cold water and sanitary
hot water, evacuation of dirty water, rain water, climatic
installations.
-
Chimney and flue work.
-
Rules and processes for calculating chimneys with
natural draft and appendices.
-
Chimney for homes.
-
Ventilation of homes.
2 .2 Use of new fuel oil types
This boiler and its burner are compatible with the new
domestic oil containing FAME (Fatty Acid Methyl Ester)
and with non-road diesel (NRD*) on the condition they
respect the rules for the use and storage of this fuel
(refer to document n°1474 supplied with the appliance
and the user instructions, §
Rules for using and storing
domestic fuel containing FAME
).
only FranceNe pas traduire:only France
2 .3 Unpacking and reserves
2 .3 .1 Receipt
When the courier is present, carefully check the general
appearance of the appliances, check that the outdoor
unit has not been in horizontal position.
In the event of disagreement, write to the courier within
48 hours mentioning all reserves and send a copy of
this letter to the After Sales Department.
2 .3 .2 Handling
The outdoor unit must not be in horizontal position
during transport.
Transport in horizontal position creates a risk of damage
to the inner tubes and the compressor suspensions.
Damage caused by transport transport in horizontal
position is not covered by the warranty.
If required, the outdoor unit may be tilted only when
being moved by hand (to get it through a doorway, or
up stairs...).
This operation must be carried out carefully and the
appliance must be immediately returned to the vertical
position.
2 .3 .3 Accessories supplied
1
Elbow
for the evacuation of the
condensates
2
Plugs (x2)
(depending on
model)
3 Allen key
to open the valves
figure 12 - Accessories supplied with the external unit
1
3
2
4
1
2
3
5
Outdoor sensor
To monitor the outdoor
temp
figure 13 - Accessories supplied with
the hydraulic module
5
6
Installation and operating manual
"
1605 - EN
"
- 13 -
alfea hybrid duo heat pump oil low NOx CH