with a free cross section that cannot be obstructed of at
least 50 cm
2
that opens onto the lower part and a used
air outlet (B) with a free cross section that cannot be
obstructed of at least 100 cm
2
positioned on the upper
part and opening directly outdoors (see
Refer to
Departmental sanitary Regulations Type
(RSD), article 53.4 .
The atmospheric conditions in the room must not be
humid; humidity is damaging for electrical appliances.
If the ground is humid or soft, use a base of sufficient
height
To facilitate the servicing operations and permit access
to the various parts, it is recommended that sufficient
space be left all around the hydraulic module.
"
The warranty on the heater will not cover any
installation of the appliance in a chlorine rich
atmosphere (hairdressers, launderette, etc.) or
any other corrosive vapours .
This equipment may not be installed in a bathroom or a
shower room.
Be careful of the presence of inflammable gas close
to the heat pump when it is installed, especially when
brazing is required. The appliances are not antiexplosion
and must therefore not be installed in an explosive
atmosphere.
-
To avoid any condensation inside the condensor only
remove the refrigerating circuit plugs
when making
refrigerating connections
-
If the refrigerant connection only occurs at the end of
the installation, be sure that the refrigerant circuit caps*
remain in place and tight throughout the installation
duration
* (Hydraulic module side and outdoor unit side)
-
After the work is carried out each time on the
refrigerating circuit, and before final connection, refit
the Plugs to avoid any pollution of the refrigerating
circuit (sealing with adhesive is not allowed).
2 .6 .2 Reversible chamber door
The chamber door is fitted with the hinges on the left
as standard. For it to open in the opposite direction,
change over the side on which the hinges and pins are
fitted.
-
Remove the burner.
-
Remove the chamber door.
Remove the 4 door attachment screws.
Remove the upper pin.
-
Raise and tilt the door.
"
Do not hold the door by its thermal protection .
-
-
Remove the hinges and fix them on the other
side.
-
Remove the lower pin and position it on the RH side
of the door
-
Refit the chamber door and attach the upper pin.
"
Lightly tighten the screws of the closing door .
figure 17 - Reversible chamber door
2 .6 .3 Evacuation pipe
(see
The evacuation pipe must comply with the regulations
in force
The evacuation pipe must have suitable dimensions.
Minimum cross section required = 2.5 dm
2
for a chimney
of between 5 and 20 m in height, or a ball valve of 16
cm or Ø 18 cm.
The pipe must only be connected to a single appliance.
The pipe must be waterproof.
The pipe must be correctly thermally insulated in order
to avoid any problems of condensation; otherwise the
pipe must have a tube fitted with a system for collecting
the condensates.
Use a good quality watertight tube that is compatible
with the fuel used, possibly with a system for collecting
the condensates.
Installation and operating manual
"
1605 - EN
"
- 17 -
alfea hybrid duo heat pump oil low NOx CH