2 .11 .6 Electrical connections on the
outdoor unit side for 3 phase model
Access to the connector terminals
-
Remove the front panel. Remove the screws and the
cover of the front panel.
figure 35 - Access to the terminal block
of the three phase outdoor unit
Remove the screws
and push downwards
Remove the front
panel
Terminal
block
figure 36 - Terminal block connections
of the three phase outdoor unit
1
INDOOR UNIT
POWER
2 3 L1 L2 L3 N
Terminal
block
Inter-connection
between outdoor unit
and hydraulic module
General electrical
power supply
figure 37 - Finalise the connection
of the three phase outdoor unit
Cable
clamp
cables
(power supply and
interconnection)
front
lower
Side
rear
figure 38 - Passages of the cables and refrigerating con-
nectors of the three phase outdoor unit
-
Make the connections as per the diagram(s) (
and
-
Use the cable clamps to avoid any accidental
disconnection of the conductive wires.
-
Obstruct the space at the cable inlet in the outdoor unit
with the insulating plate.
Installation and operating manual
"
1605 - EN
"
- 29 -
alfea hybrid duo heat pump oil low NOx CH