![Asus DS300f Скачать руководство пользователя страница 402](http://html.mh-extra.com/html/asus/ds300f/ds300f_user-manual_26724402.webp)
383
Chapter 10: Troubleshooting
Reported Event
Corrective Action
Transition was switched
to rebuild
Transition changed to rebuild because the logical
drive went critical.
Watermark
Migration has detected/
cleared stale NV
Watermark
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
Array was incomplete due
to missing NV Watermark
RAID migration was interrupted by a shutdown.
If array is online, try migration again. See page 158
(ASUS Storage Management) or page 232 (CLU).
If array is offline, delete and recreate array. See
page 154 and page 149 (ASUS Storage
Management) or page 229 and page 225 (CLU).