![Asus DS300f Скачать руководство пользователя страница 267](http://html.mh-extra.com/html/asus/ds300f/ds300f_user-manual_26724267.webp)
248
Chapter 6: Management with the CLU
Viewing Fibre Channel Port Statistics
To view port statistics:
1. From the Main Menu, highlight
Fibre Channel Management
and press Enter.
2. Highlight
Fibre Channel Ports
and press Enter.
3. Highlight the port you want and press Enter.
4. Highlight
Fibre Channel Port Statistics
and press Enter.
This screen displays statistics for this port. There are no user settings on this
screen.
Clearing Statistics
To clear Fibre Channel statisti
cs, see ―Clearing Statistics‖ on page 275.
Property Definitions
Definitions of the properties for which statistical information is reported appears in
the list below.
•
TimeLastReset
– Time in minutes since the system has been running.
•
FramesSent
– Number of frames sent since last reset.
•
FramesReceived
– Number of frames received since last reset.
•
WordsSent
– Number of words sent since last reset.
•
WordsReceived
– Number of words received since last reset.
•
LIPCount
– Loop Initialization Primitive Sequence. This primitive sequence
applies only to the arbitrated loop topology. It is transmitted by an L_Port to
initialize or re-initialize the loop.
•
NOSCount
– Not Operational Primitive Sequence. This primitive sequence
is used during link initialization between two N_Ports in the point-to-point
topology or an N_Port and an F_Port in the fabric topology.
NOS is sent to indicate that the transmitting port has detected a link failure or
is offline. The expected response to a port sending NOS is the OLS primitive
sequence.
•
ErrorFrames
– FC devices propagate handshake signals back-and-forth
requesting and acknowledging each byte transferred. FC transfers occur in
one frame of data at a time. In this case, the value reflects the number of
frames with errors.
•
DumpedFrames
– This field specifies the number of frames dumped due to
a lack of host buffers.
•
LinkFailureCount
– Number of times the link has failed. Can be caused by
a disconnected link or a bad fiber element.
•
LossSyncCount
– Number of times a loss of sync has occurred since last
reset.
Содержание DS300f
Страница 1: ...ASUS Storage DS300f DS300i User Manual Version 1 0 ...
Страница 10: ...x Language 178 Closing Smart NAS Console 178 ...
Страница 27: ...8 Chapter 1 Introduction to ASUS Storage ...
Страница 57: ...3 8 Chapter 2 ASUS Storage Installation ...
Страница 73: ...54 Chapter 3 ASUS Storage Setup ...
Страница 164: ...14 5 Chapter 4 Management with ASUS Storage Management ...
Страница 221: ...202 Chapter 5 SmartNAVI ...
Страница 235: ...216 Chapter 6 Management with the CLU Figure 4 Controller Status LED Controller Status ...
Страница 337: ...318 Chapter 8 Maintenance ...
Страница 425: ...406 Chapter 11 Support ...
Страница 433: ...414 Appendix A Setting up NAS Network Drives ...
Страница 449: ...430 Index ...