Time Code
114
Warning
Remedy
TC magazine not recognized
use a suitable 435 magazine
TC not set to NDF/RT
reset TC at current frame rate
and swiched to RT/NDF
RT (Real Time)
is 24, 25, 30 fps
NDF (Nondrop Frame)
is 23,976 and 29,97 fps
TC-LED not recognized
attach or check TC-module
TC not buffered
reset TC;
either the TC buffer battery is used up
or the power supply was insufficient
or interrupted, or over 10 hours
passed since TC was last set
3rd Display Digit for TC Warnings
Warning
Remedy
error in external synchronization
repeat external synchronization
check LTC-signal
TC switched on but not set
set TC via CCU-1, LCC,
or external synchronization
TC not ready
have functional expansion module
(FEM) checked
4th Display Digit for TC Warnings