8
Operation manual
3 Installation
3.1 Sensor location
To avoid measuring errors due to gas/air entrainment or to a partly filled pipe, please observe the following:
Horizontal (standard) mounting
The sensor tube must always remain full. The best way to achieve this is to locate the sensor in a low section of
pipe, see the following picture. It is recommended to install the sensor in a section of straight pipe with at least 5
times the pipe diameter before sensor and 3 times after sensor.
Pipe reducers
If the pipe diameter is not the same as the diameter of sensor, then pipe reducers can be used. So as not to lose
accuracy of the measurement, the slope of reducers should not exceed 8
°
.
5 DN
3 DN
5 DN
3 DN