Electromagnetic Flowmeter M-910
50
Operation manual
DN (mm)
PN (bar)
D (mm)
A (mm)
L (mm)
Weight (kg)
10
16
90
140
150
3
15
16
95
145
200
3
20
16
105
150
200
3,5
25
16
115
155
200
3,5
32
16
140
165
200
5
40
16
150
175
200
6
50
16
165
185
200
7
65
16
185
200
200
9
80
16
200
215
200
11
100
16
220
235
200
12
125
16
250
265
300
22
150
16
285
295
300
24
200
16
340
355
400
35
250
10
395
435
400
42
300
10
445
485
500
56
350
10
505
535
500
70
400
10
565
580
500
95
500
10
670
695
500
120
600
10
780
800
600
160
700
10
895
900
700
230
800
10
1015
1010
800
330
Table 1: M910 dimensions and weights – DIN flanges
9.2 Used materials
Electromagnetic flowmeter is made from materials, which meet international standards and conventions.
Liner:
Hard rubber
as standard
Teflon - PTFE
Electrodes
CrNi (stainless) steel 1.4571 as standard
Hastelloy C276
Tantalum
Sensor tube
Stainless steel 1.4201,
dimensions according to DIN 17457
Flange
Steel 1.0402 or higher,
dimensions according to DIN 2501 (BS 4504), ANSI
B16.5