3
Intended Use
The Amputee Sling is a product intended for assisted
transfer of single and double amputee patients/
residents with limited ability to move. The Amputee
Sling should be used together with ArjoHuntleigh lift
devices in accordance with the Allowed Combinations
specifi ed in the
Instructions for Use (IFU)
.
Products made of All Day Mesh and Mesh materials
are intended to be used when bathing.
Products made of All Day Mesh and All Day
materials are suitable to sit on longer periods. Article
MAA2091M enables toileting.
The Amputee Sling shall only be used by appropriately
trained caregivers with adequate knowledge of the care
environment, and in accordance with the instructions
outlined in the
Instructions for Use
.
The Amputee Sling is intended to be used in hospital
environments, nursing homes, other healthcare
facilities and home care.
The Amputee Sling should only be used for the
purpose specifi ed in this
Instructions for Use
. Any
other use is prohibited.
Patient/Resident Assessment
We recommend that facilities establish regular
assessment routines. Caregivers should assess each
patient/resident according to the following criteria
prior to use:
• Patient/resident sits in wheelchair
• Has no capacity to support herself/himself at all
• Cannot stand unsupported and is not able to bear
weight, not even partially
• Dependent on caregiver in most situations
• Physically demanding for caregiver
• Stimulation of remaining abilities is very important
Or, for a patient/resident who:
• Is
passive
• Might be almost completely bed ridden
• Often stiff, contracted joints
• Totally dependent on the caregiver
• Physically demanding for caregiver
• Stimulation and activation is not a primary goal
Safe Working Load (SWL) for Amputee Sling:
• MAA2050M, MAA2080M: 190 kg (418 lbs);
• MAA2090M, MAA2091M, MAA4040M,
MAA4070M, MAA4080M, MLA7000,
MLA7000A, MAA7090M: 272 kg (600 lbs).
The right type and size of slings should be used after
proper assessment of each resident’s size, condition
and the type of lifting situation.
If the patient/resident does not meet these criteria an
alternative equipment/system shall be used.
Expected Service Life
The expected service life of Amputee Sling is the
maximum period of useful life. The expected life of
the sling is dependent on the actual use conditions.
Therefore, before use, always make sure that the
sling does not show signs of fraying, tearing or other
damage and that there is no damage (i.e. cracking,
bending, breaking). If any such damage is observed,
do not use the sling. If you have any doubts about sling
safety, as a precaution and to ensure safety, do not use
the sling.
The expected service life of the Amputee Slings:
• Service
Time:
- 1,5 years for slings made of All day material;
- 2 years for slings made of all other materials;
• Shelf
Time:
- 5 years.
EN
Содержание MAA2050M
Страница 18: ...18 ZH...
Страница 19: ...19 IFU ZH...
Страница 20: ...20 6 ArjoHuntleigh 5 IFU IFU 1 2 4 3 5 8 6 7 9 10 11 12 13 14 15 1 1 ZH...
Страница 24: ...24 2 1 2 7 8 24 9 10 11 12 7 8 9 10 11 ZH...
Страница 25: ...25 4 6 22 13 10 14 4 6 12 13 14 ZH...
Страница 26: ...26 32 15 9 16 16 17 18 10 15 16 17 18 ZH...
Страница 27: ...27 19 12 20 17 21 13 22 19 20 21 ZH...
Страница 28: ...28 23 22 23 IFU IFU 7 ZH...
Страница 30: ...30 IFU ArjoHuntleigh on page 22 ZH...
Страница 31: ...31 70 C 158 F 93 42 EEC CE REF XXXXXX X X REF XXXXXXX PES PE PU PA SWL IFU REF ZH...
Страница 92: ...Intentionally left blank...
Страница 93: ...Intentionally left blank...
Страница 94: ...Intentionally left blank...