The
Burner stop temperature
setting should be set so that the fuel in the
burner screw does not overheat the accumulator. The boiler water
temperature setting should be set higher than the burner stopping temperature
in order to increase the burner effect.
The boiler return water should be set at 70°C with an automatic control valve
(E.g. Laddomat, ESBE Series VTC500) or a heating circuit control device.
17.10 GSM alarms
The user can define two telephone numbers where SMS alarms/warnings are
sent. The SMS PROVIDER -button allows you to enter the operator
messaging centre number. You should enter this number in case SMS alarms
are not sent.
18.
Troubleshooting
Alarm messages indicate the cause of each alarm. See the following chart
for possible sources of problems and solutions. The source of the problem
should be located and corrected before restarting the system.
Alarm
Cause of problem
Inspect
Alarm!
Boiler water
over temperature
1. Boiler overheat protection
has been set off.
2. The BioJet burner overheat
protection has been set off.
Inspect the overheat protection
status and acknowledge if
necessary. Determine the cause
of overheating (e.g. circulation or
cooling pump) before restarting
the system.