v2.00
Ariterm Oy
21.5.2013
30
for the set time, but the funnel
sensor has not detected any fuel,
the bar discharger is activated for
the set duration.
Running time
10s
0-60s
Bar discharger operating time.
If BAR DISCHARGER is selected in the
OPTIONS
-menu, the
SETTINGS
-
page will also display the
BAR DISCHARGER
-settings. When the storage
auger has run for the set
Start delay
-time, but the funnel sensor has not
detected any fuel, the bar discharger is activated for the set duration. The bar
discharger runs for the duration of the
Running time
-setting. Time should be
set so that the cylinder performs one reciprocating motion at most.
17.2 Sweeping settings
Figure 18. SWEEPING settings
Setting
Factory
setting
Setting
frequency
Function
Running time
(minutes)
4 min
0-60 min
Sweeping duration
Pause time
(minutes)
60 min
0-60 min
Sweeping pause duration.
The sweeping motor moves spirals inside the convection pipes in a
reciprocating, horizontal motion. The sweeping motor is run for a set time
(
Running time
-setting) in set intervals (
Pause time
-setting). NOTE! The
boiler should also be swept manually. See boiler instructions.