![Ariterm Arimatic 151 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/ariterm/arimatic-151/arimatic-151_user-manual_2972140027.webp)
v2.00
Ariterm Oy
21.5.2013
26
14.3 Wood chip auger
Burner screw diameter 159mm, bore diameter 135mm, auger elevation angle
20° rotation speed 11.5rpm. Auger production 0.486m3/h, corresponding to
317kW (chip 750kWh/m3, boiler efficiency 87%).
40kW system
Effect
Power
kW
Burner
screw
Primary fan Secondary
fan
Upkeep
0.5
0%
0%
21%
9kW
2.8
20%
15%
50%
20kW
6.3
30%
25%
75%
30kW
9.5
40%
40%
100%
40kW
12.6
50%
55%
60kW system
Effect
Power
kW
Burner
screw
Primary fan Secondary
fan
Upkeep
0.5
0%
0%
21%
12kW
3.7
25%
15%
50%
30kW
9.4
40%
35%
75%
45kW
14.1
55%
45%
100%
60kW
19.0
60%
65%
80kW system
Effect
Power
kW
Burner
screw
Primary fan Secondary
fan
Upkeep
0.5
0%
0%
21%
17kW
5.4
30%
20%
50%
40kW
12.6
50%
45%
75%
60kW
19.0
60%
60%
100%
80kW
25.2
65%
65%
120kW system
Effect
Power
kW
Burner
screw
Primary fan Secondary
fan
Upkeep
0.5
0%
0%
21%
25kW
7.9
35%
20%
50%
60kW
19.0
50%
45%
75%
90kW
28.3
65%
60%
100%
120kW
37.8
70%
55%
150kW system
Effect
Power
kW
Burner
screw
Primary fan Secondary
fan
Upkeep
0.5
0%
0%
21%
30kW
9.4
35%
20%
50%
75kW
23.6
50%
45%
75%
110kW
34.7
65%
60%
100%
150kW
47.3
80%
75%