performs a cleaning movement, where the linear actuator moves from one end
to the other.
The grate pulses (running and pause time) is determined for five power points
which the programme uses for calculating times for other power levels.
17.7 Shunt control (Heating circuit control)
Figure 24. SHUNT CONTROL -settings.
Setting
Factory
setting
Setting
frequenc
y
Function
Water temperature
True
value
-
Supply water temperature
Water temperature
35°C
0-100°C
Supply water temperature setting when
shunt control is in the NOT IN USE mode.
Water temperature
sensor scaling min.
-10°C
-
150…15
0°C
Supply water temperature sensor scaling
NOTE! Requires Maintenance level
password.
Water temperature
sensor scaling max.
150°C
-
150…15
0°C
Supply water temperature sensor scaling
NOTE! Requires Maintenance level
password.
Out temperature
True
value
-
Outdoor temperature.
Out temperature
sensor scaling
min.
-50°C
-
150…15
0°C
Outdoor temperature sensor scaling.
NOTE! Requires Maintenance level
password.
Outdoor
temperature sensor
scaling max.
50°C
-
150…15
0°C
Outdoor temperature sensor scaling.
NOTE! Requires Maintenance level
password.