Turn the Control
Switch ON.
Is the indicator
light illuminated?
1. Check indicator light bulb. Re-
place if necessary.
2. Remove the Aqua-Hot’s ACCESS
COVER.
3. Check Aqua-Hot fuses (E & F) for
continuity.
4. Check DC power supply at the
“Power Post” and “Ground Post”.
5. Attempt heater restart.
NO
Is the Diesel Burn-
er’s “MOTOR”
operating?
Yes
1. Remove the Aqua-Hot’s Access
Cover
2. Remove the “Thermostat Access
Panel”
3. Check the Diesel Burner’s “VDC
High-Limit Thermostat” for conti-
nuity
NOTE: This thermostat protects
against overheating temperatures.
Yes
1. Remove the Aqua-
Hot’s Access cover.
2. Check the Aqua-
Hot fuse (F) for
continuity. Replace
if necessary.
NOTE: The Indicator
light will illuminate for
only 30 seconds if fuse
(F) is blown (open
circuit)
3. Attempt heater restart
NO
Check the Diesel Burner’s
“VDC Control Thermo-
stat” for continuity.
Is there continuity
across the
thermostat?
Yes
1. Replace Thermostat.
NOTE: Aqua-Hot operat-
ing temperature must be
below 175ºF when checking
the “VDC Control Thermo-
stat” for continuity.
2. Attempt Heater Restart
1. Replace the Thermostat.
2. Attempt Heater Restart
NO
Is there continuity
across the
thermostat?
NO
Yes
S
ECTION
8: D
IESEL
-B
URNER
C
OMPONENTS
/T
ROUBLE
S
HOOTING
Содержание AHE-100-02S
Страница 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Страница 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Страница 76: ... Page 76 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B APPENDIX A WIRING DIAGRAM ...
Страница 77: ... Page 77 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B APPENDIX A WIRING DIAGRAM ...
Страница 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Страница 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...