— Page 74 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
1. On the Front-Side of Aqua-Hot -
1. Electric element
2. Circulation/Stir pump
c. Copper plumbing
d. Tank ports
- It might be necessary to cut away some of the insulation around the tank
ports to locate the leak.
e. Pump
6. Burn Chamber Leak
a. If Antifreeze is running out of the tip of the exhaust pipe remove the burner, and
combustion chamber and inspect inside the burn chamber for leaks.
S
ECTION
9: G
ENERAL
T
ROUBLESHOOTING
I
F
T
HERE
I
S
A
NTIFREEZE
L
EAKING
:
NOTE: To find an antifreeze leak, the system must be Hot (up to operating temperature)
Or pressurized to 17 PSI.
Inspect the following components on the Aqua-Hot Heating System for Leaks: