— Page 13 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
4: E
XHAUST
S
YSTEM
R
EQUIREMENTS
Because the Aqua-Hot’s exhaust is hot and must be kept
away from any heat-sensitive material, the exhaust system
should be checked to ensure that it continues to meet the
following requirements:
The exhaust must not be directed downward as a fire
could result when parked in dry, grassy areas.
The exhaust must not terminate underneath the vehicle,
underneath an open-able window or vent, in the awning
area of the motor home (if applicable), or near slide-out
areas.
The exhaust must be able to freely exit away from the
vehicle without any obstructions.
1 3/4” - 2” standard automotive-type exhaust piping
should be used with a maximum of two 90-degree pipe
bends and should not exceed 20 feet.
The 3-inch and 4-inch black-pipe nipples and the ex-
haust elbow - originally supplied with the Aqua-Hot,
must be present.
Figure 5
Содержание AHE-100-02S
Страница 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Страница 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Страница 76: ... Page 76 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B APPENDIX A WIRING DIAGRAM ...
Страница 77: ... Page 77 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B APPENDIX A WIRING DIAGRAM ...
Страница 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Страница 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...