DC High-Limit Thermostat:
The DC high-limit thermostat serve as a safety measure in
the event that the diesel-burner continues to operate after the
maximum operating temperature is reached. The high-limit
thermostat allow the current for the diesel-burner to pass
through it until the boiler tank reaches a temperature of
230°F. Should this temperature be reached, the high-limit
thermostat blocks the current to the diesel-burner’s fuel sole-
noid valve, which prevents the diesel-burner from operating.
Troubleshoot the DC high-limit thermostat if the following
condition has occurred:
The fuel solenoid on the diesel-burner fails to operate.
Troubleshooting:
1.
Place a jumper wire between the blue and purple wires
on the diesel-burner’s wire harness to bypass the high-
limit thermostats. Check the Aqua-Hot for normal oper-
ation.
NOTE:
Bypassing the high-limit thermostats is for testing
only and must not be used for the Aqua-Hot’s nor-
mal functioning.
2.
Disconnect the DC high-limit thermostats’ wires, then,
using an ohmmeter, check the thermostat for continuity.
If there is no continuity, complete the following, follow
the instructions in this section to replace the high-limit
thermostat.
Replacement Procedure:
F
AILURE
TO
DISCONNECT
ALL
POWER
SUPLIES
AND
/
OR
TO
ALLOW
THE
HEATER
TO
COOL
BEFORE
SERVICING
COULD
CAUSE
SERIOUS
DAMAGE
OR
PERSONAL
INJURY
.
1.
Ensure that the Aqua-Hot has been completely shut down
and that all power sources have been disconnected. Also,
because this replacement procedure will involve the boiler
tank and the potential for hot coolant, be sure the heater
has adequately cooled.
2.
Disconnect the defective thermostat’s wires by separating
the quick-disconnect terminals.
3.
Using a 1/4” nut driver, unscrew the two screws securing
the control thermostat to the Aqua-Hot’s boiler tank ther-
mostat mounting bracket.
4.
Install the replacement thermostat into the thermostat
mounting bracket and secure with the two screws previ-
ously removed.
5.
Inspect the quick connectors on the thermostat wires. Re-
place if necessary. Re-Connect the thermostat’s wires
(blue and purple).
6.
Test the Aqua-Hot for normal operation.
Figure 11
Note:
If a screw longer than 1/4” is used to secure the
thermostat in place, it may cause the thermostat mounting
bracket to be pushed away from the boiler tank, and may
result in overheating.
Note:
If the control and overheat thermostat wires are
hooked up to the wrong thermostat, the diesel burner will de-
fault every time the heater reaches the maximum operating
temperature.
Содержание AHE-100-02S
Страница 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Страница 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Страница 76: ... Page 76 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B APPENDIX A WIRING DIAGRAM ...
Страница 77: ... Page 77 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B APPENDIX A WIRING DIAGRAM ...
Страница 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Страница 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...