Horizontal downflow pleated cartridge dust collector
14
12 ELECTRICAL CONNECTIONS
12.1 Check list
Prior to starting the collector for the first time, the check list must be followed to ensure a proper
continuous operation.
1 .
Remove all objects in and around the inlet and outlet.
2.
Check if all accessories and optional equipment are installed correctly.
3.
Ensure the compressed air gauge indicates 90 psig. Check for air leaks.
12.2 Electrical connections
WARNING!
The electrical connection must be executed by a qualified
electrician and with respect to codes and regulations. For
safety measures, shut off power supply to the collector prior
to perform the installation.
1.
Ensure all electrical connections sealed and power is available.
2.
Check remote control connections (if any) and that all breakers are OFF.
3.
Switch ON power to the unit.
4.
Start the fan and shut off immediately. Check fan rotation. The rotation is indicated on the
label of the fan.
5.
Adjust the adequate air volume using the air damper (if any) at the fan outlet.
Note :
An excessive air volume may shorten the life expectancy of the cartridges or cause an
electrical power surge on the fan and the system.
12.3 Optional equipment
Quick clip drum, ramp and buggy
This option eases the removal of dust
filled 55 gallon drums. The quick clip
flange allows fast changes of drums
without the help of tools. The buggy
permits easy displacement of full drums.
QUICK CLIP
LOWER FLANGE
DRUM
DOLLY
RAMP
GASKET SEAL