Horizontal downflow pleated cartridge dust collector
20
1.
Remove the cartridge round access door by unscrewing the knob. Ensure that you do not
damage the rubber gasket seal around the access door. Start this procedure from the top
row of cartridges.
2.
Remove the nut and washer from the yoke’s threaded rod. Set them aside.
3.
Slowly twist the cartridge half a turn to remove the deposit of dust that could be on top of
the cartridge.
4.
Gently slide out the cartridge along the yoke. Repeat steps 3 and 4 if it is a modle with two
(2) cartridges deep.
5.
Disposal of dirty cartridges must be done according to environmental regulations.
6.
Check for any excessive dust accumulation in the hopper and clean if necessary.
Follow these steps to install the new cartridges.
Note :
older type MAXIFLO dust collectors are equipped with open/open and open/closed type
cartridges. More recent type MAXIFLO dust collectors are equipped with open/open and open/
open type cartridges. Ensure you order the proper type of cartridges for replacement.
Ensure that you have the same cartridges as originally installed in the collector.
1.
Slide the cartridges onto the yokes starting the open/open type. Check for the integrity of the
cartridge seal.
2.
Install the washer and nut that you set aside earlier. Screw in the assembly for a proper seal.
3.
Install the access door back onto the cabinet making sure the rubber gasket seal is well
attached. Screw the knob in and asses all components are sealed.
4 .
Switch power and compressed air system back on before starting the unit.