Horizontal downflow pleated cartridge dust collector
21
17 COMPRESSED AIR SYSTEM
WARNING!
Shut off the compressed air valve and bleed the line feeding
the collector prior to performing maintenance on the unit.
1.
Periodically check the compressed air components such as the air dryer and regulator.
Replace in line air filters feeding compressed air to the unit.
2.
Remove any humidity that may be present in the compressed air lines using the
recommendations of the manufacturer.
3.
With the compressed air system switched on, check the cleaning valves, the activating
solenoids, pneumatic hoses and possible leaks. Correct any problem and replace defective
parts.
17.1 Explosion vent
If the system requires an explosion vent, the following components must be checked.
1.
Explosion vent must be free of any obstruction.
2.
Check for corrosion or rust.
3.
Check for any physical or mechanical damages.
4.
Ensure the sign is still applied to the door.
5 .
Ensure the explosion vent is protected from ice and snow.
6.
Check for cracks or metal fatigue.
7.
Ensure there are no missing parts.
8.
Swing door open and ensure mechanical parts are well lubricated.
9.
Ensure the door is well sealed against the dust collector.
17.2 Control panel
The sequencer is designed to control the air pulse cleaning valves (jet pulse). It allows the
programming of a cleaning sequence which will be repeated permanently acting on the solenoid
valves. The pilot indicating lights (diodes) show which solenoid is powered. For units equipped with
auxiliary accessories (rotary valves, screw conveyors), refer to the documents included with the
control panel.