Horizontal downflow pleated cartridge dust collector
26
Problem
Probable cause
Solution
Cleaning cycle light
is ON but nothing
happens.
Solenoids are not
wired properly
Check wiring between sequencer card and solemoids.
Defective solenoids
Check if solenoids work properly.
Cleaning cycle light
is ON but nothing
happens.
Defective sequencer
card
Check if sequencer card is defective by following
the manufacturer’s recommendations.
The alarm light is
ON (DCT-1000)
Alarmvalue is too low
Adjust to a higher value.
Too much
pressure loss
Check and clean compressed air system. Replace car-
tridges if normal pressure does not resume to normal.
The pneumatic data
hose is unplugged,
broken or clogged.
Check the pneumatic hoses connected to the DCP
pressure module for any leak or tear.
Replace if necessary.