RAIDER
2000
-
16
-
OPERATOR FOR SWING GATES
English
PRELIMINARY INSTALLATION OPERATIONS
2.
Preparing electrical connections
2.1
Warning
!
The system must only be installed by skilled personnel quali
fi
ed in compliance with the
regulations of the country of installation
(CEI 64 - 8 / EN 60335-1 standards).
The metallic components of the structure (i.e. the gate and pillars) must have an earth connection.
Prepare the electrical connection of the controller and safety devices in accordance with the lay-out in
fi
g.3
. Please heed
the warnings provided in this manual and comply with the instructions attached to the installed components. Prepare the
cableways (external or buried) up to where the devices will be installed .
The electric component
box
should be fully sealed and should be placed at least 30 cm from the ground. Cable outlets should
point downwards. The cableway joints to the box should be sealed to prevent the entry of dampness, insects or small animals.
POWER SUPPLY: 230 V AC
- Cable 3x1.5 mm
2
(minimum section). The cable cross-section should be calculated in
accordance with the length of the line.
If it is necessary to use automation power supply cable sheathing, apply this sheathing before connecting the cable itself
to the derivation boxes.
IMPORTANT! Always install, upstream of the line, a mains switch which guarantees a multipole cut-off with minimum
contact opening of 3 mm (connect it to a 6 A differential overload switch with sensitivity of 30 mA).
Operator/control unit connection
- given that the operator is
fi
tted with an encoder use of a shielded cable is
recommended
(Aprimatic catalogue,
additional shielded cable, 6 poles, length 10 m)
.
The command and control accessory devices and the emergency button should be placed within sight of the automation,
away from moving parts and at a minimum height of 1.5 m from the ground.
Aprimatic
9
6A
lc= 30mA
230 VAC
A rimatic
p
A rimatic
p
!
4
3
6
1
8
e
d
c
f
a
e
b
5
7
f
b
g
5
2
2
Fig. 3
SYSTEM LAYOUT
1
control unit..............................................
a
2 x 1.5 mm
2
+ earth
2
operator ..................................................
b
2x1.5 mm
2
3
antenna 433.92 MHz ..............................
c
supplied cable
4
flashing light ...........................................
d
2 x 1 mm
2
5
photocell pair ..........................................
e
transmitter 2 x 0.75 mm
2
; receiver 4 x 0.75 mm
2
6
key switch...............................................
f
3 x 0.75 mm
2
7
OPTIONAL control devices ....................
f
3 x 0.75 mm
2
Proximity reader
*
, Magnetic card reader
*
, Electronic keypad
*
8
electric lock
*
...........................................
g
2 x 1.5 mm
2
9
transmitter
*
optional accessory (see the sales brochure)