Mobile Digital Video Recorder
7
NC/NO (Relay Alarm Outputs):
The DVR can activate external devices such as buzzers or lights. Connect the device
to the
C
(Common) and
NC
(Normally Closed) or
C
and
NO
(Normally Open) connectors.
NC/NO
is a relay output
which sinks 0.5A@125VAC and 1A@30VDC.
See
Chapter 3
─
Configuration
for configuring alarm output.
ARI (Alarm Reset In):
An external signal to the
Alarm Reset In
can be used to reset both the Alarm Out signal.
Mechanical or electrical switches can be wired to the
ARI
(Alarm Reset In) and
G
(Ground) connectors. The threshold
voltage is below 0.3V and should be stable at least 0.5 seconds to be detected. Connect the wires to the
ARI
(Alarm
Reset In) and
G
(Ground) connectors.
Connection
AI (1 to 8)
Alarm Inputs 1 to 8
G
Chassis Ground (3 connectors)
ARI
Alarm Reset In
NC
Relay Alarm Output (Normally Closed)
NO
Relay Alarm Output (Normally Open)
C
Relay Common
Panic
Connection
PANIC
Panic Recording Input
G
Chassis Ground
Network Port
CAUTION: The network connector is not designed to be connected directly with cable or wire
intended for outdoor use.
Factory Reset Switch
The DVR has a
Factory Reset
switch to the right of the Network port on the rear panel. This
switch will only be used on the rare occasions that you want to return all the settings to the original
factory settings.
CAUTION: When using the Factory Reset, you will lose any settings you have saved.
To reset the unit, you will need a straightened paperclip:
1. Turn the DVR off.
2. Poke the straightened paperclip to the unlabeled hole in the right of the Network port.
3. Hold the switch until the DVR turns on and live monitoring screen appears.
4. Release the reset switch. All of the DVR’s settings are now at the original settings it had when it left the factory.
Your DVR is now ready to operate. Refer to
Chapter 3
─
Configuration
and
Chapter 4
─
Operation
.
An external signal to the
PANIC
can be used to start panic recording of all camera channels. Turing the
signal Off stops panic recording. Mechanical or electrical switches can be wired to the
PANIC
and
G
(Ground)
connectors. The threshold voltage is below 0.3V and should be stable at least 0.5 seconds to be
detected.
The DVR can be networked using the 10/100Mb Ethernet connector. Connect a Cat5 cable with an RJ-45
jack to the DVR connector. The DVR can be networked with a computer for remote monitoring, searching,
configuration and software upgrades. See
Chapter 3
─
Configuration
for configuring the Ethernet
connections.