FST 500 Manual
- Page 74 -
08 Reserved
09 Output Current (A)
10 Display program operation (0. xxx), Fwd, or Rev
★
The parameter can be set to display the user-defined value. (where v = H x Pr.65 )
Pr.65
※
Coefficient K Unit: 0.01
Settings 0.01 to 160.0 Factory Setting: 1.00
●
The coefficient K determines the multiplying factor for the user-defined unit.
●
The display value is calculated as follows:
Display value = output frequency x K
●
The display window is only capable of showing four digits, yet you could use Pr.65 to create
larger numbers. The display windows uses decimal points to signify numbers up to three digits
as illustrated in next page:
Display
Number Represented
9999
The absence of a decimal point indicates a four-digit integer.
999.9
A signal decimal point between the middle and the right-most numbers is a true
decimal point. For example, the number 123.4 would be displayed as “123.4”.
9999.
A single decimal point after the right-most number is not a true decimal point; instead it
indicates that a zero follows the right-most number. For example, the number 12340
would be displayed as “1234.”
999.9.
Two decimal points (one between the middle and the right-most numbers, and one
after the right-most number) are not true decimal points; instead they indicate that two
zeros follow the right-most number. For example, the number 345600 would be
displayed as “345.6.”.
Pr.66 Communication Frequency Unit: 0.1 Hz
Settings 0.00 to 400.0 Hz Factory Setting: 0.00
★
This parameter defines the Master Frequency when the AC drive is controlled by the
communication interface.
Содержание FST-500 Series
Страница 8: ...FST 500 Manual Page 8 1 1 3 External Parts and Labels...
Страница 9: ...FST 500 Manual Page 9 1 1 4 Remove instructions...
Страница 17: ...FST 500 Manual Page 17...
Страница 22: ...FST 500 Manual Page 22 2 4 Control Terminal Wiring Factory Settings...
Страница 27: ...FST 500 Manual Page 27 3 1 2 How to Operate the Digital Keypad LC M02E...
Страница 28: ...FST 500 Manual Page 28 3 1 3 LC M02E Reference Table for the 7 segment LED Display of the Digital Keypad...
Страница 49: ...FST 500 Manual Page 49 Commonly used V F Setting 1 General Purpose...
Страница 87: ...FST 500 Manual Page 87 ASCII mode Command message Response message RTU mode Command message Response message...
Страница 110: ...FST 500 Manual Page 110 Chapter 5 Troubleshooting 5 1 Over Current OC...
Страница 111: ...FST 500 Manual Page 111 5 2 Ground Fault 5 3 Over Voltage OV...
Страница 112: ...FST 500 Manual Page 112 5 4 Low Voltage Lv...
Страница 113: ...FST 500 Manual Page 113 5 5 Over Heat OH1 5 6 Overload...
Страница 114: ...FST 500 Manual Page 114 5 7 Keypad Display is Abnormal 5 8 Phase Loss PHL...
Страница 115: ...FST 500 Manual Page 115 5 9 Motor cannot Run...
Страница 116: ...FST 500 Manual Page 116 5 10 Motor Speed cannot be Changed...
Страница 134: ...FST 500 Manual Page 134...
Страница 135: ...FST 500 Manual Page 135...
Страница 144: ...FST 500 Manual Page 144 EMI Filter RF022M21BA RF075M43BA EMI Filter 16TDT1W4S Used on 0 5 3 HP 230V Three Phase Models...
Страница 145: ...FST 500 Manual Page 145 EMI Filter 40TDS4W4B Used on 5 7 5 HP 230V Three Phase Models...