FST 500 Manual
- Page 36 -
Parameter
Explanation
Settings
Factory
Setting
Pr.56
Reserved
Pr.57
AC Drive Rated Current Display (unit: 0.1A)
##.#
Pr.58
Electronic Thermal
Overload Relay
00: Standard Motor (self cool motor)
01: Inverter Motor (auxiliary cool fan on motor)
02: Inactive
02
※
Pr.59
Electronic Thermal
Motor Overload
30 to 300 sec
60
Pr.60
Over-Torque
Detection Mode
00: Over-Torque Detection Disable
01: Enabled during constant speed operation
until the allowable time for detection
(Pr.62) elapses.
02: Enabled during constant speed operation
and halted after detection.
03: Enabled during acceleration until the
allowable time for detection (Pr.62) elapses.
04: Enabled during acceleration and halted
After detection.
00
Pr.61
Over-Torque
Detection Level
30 to 200 %
150
Pr.62
Over-Torque
Detection Time
0.0 to 10.0 seconds
0.1
Pr.63
Loss of ACI
(4-20mA)
00: Decelerate to 0 Hz
01: Stop immediately and display "EF"
02: Continue operation by last frequency
command
00
※
Pr.64
User Defined Function
for Display
00: Display AC drive output Frequency (Hz)
01: Display User-defined output Frequency (H*Pr.65)
02: Output Voltage (E)
03: DC Bus Voltage (u)
04: PV (i)
05: Display the value of internal counter (c)
06: Display the setting frequency (F or o=%)
07: Display the parameter setting (Pr.00)
08: Reserved
09: Output Current (A)
10:Display program operation (0.xxx), Fwd, or Rev
06
※
Pr.65
Coefficient K
0.01 to 160.0
1.00
※
Pr.66
Communication
Frequency
0.00 to 400.0 Hz
0.00
Pr.67
Skip Frequency 1
0.00 to 400.0 Hz
0.00
Pr.68
Skip Frequency 2
0.00 to 400.0 Hz
0.00
Pr.69
Skip Frequency 3
0.00 to 400.0 Hz
0.00
Pr.70
Skip Frequency Band
0.00 to 20.00 Hz
0.00
Pr.71
PWM Carrier
Frequency
115V/230V/460V series: 01 to 15
(The factory setting of FST-500-7R5T4 is 10)
15
575V series: 01 to 10
6
Pr.72
Auto Restart Attempts
after Fault
00 to 10
00
Содержание FST-500 Series
Страница 8: ...FST 500 Manual Page 8 1 1 3 External Parts and Labels...
Страница 9: ...FST 500 Manual Page 9 1 1 4 Remove instructions...
Страница 17: ...FST 500 Manual Page 17...
Страница 22: ...FST 500 Manual Page 22 2 4 Control Terminal Wiring Factory Settings...
Страница 27: ...FST 500 Manual Page 27 3 1 2 How to Operate the Digital Keypad LC M02E...
Страница 28: ...FST 500 Manual Page 28 3 1 3 LC M02E Reference Table for the 7 segment LED Display of the Digital Keypad...
Страница 49: ...FST 500 Manual Page 49 Commonly used V F Setting 1 General Purpose...
Страница 87: ...FST 500 Manual Page 87 ASCII mode Command message Response message RTU mode Command message Response message...
Страница 110: ...FST 500 Manual Page 110 Chapter 5 Troubleshooting 5 1 Over Current OC...
Страница 111: ...FST 500 Manual Page 111 5 2 Ground Fault 5 3 Over Voltage OV...
Страница 112: ...FST 500 Manual Page 112 5 4 Low Voltage Lv...
Страница 113: ...FST 500 Manual Page 113 5 5 Over Heat OH1 5 6 Overload...
Страница 114: ...FST 500 Manual Page 114 5 7 Keypad Display is Abnormal 5 8 Phase Loss PHL...
Страница 115: ...FST 500 Manual Page 115 5 9 Motor cannot Run...
Страница 116: ...FST 500 Manual Page 116 5 10 Motor Speed cannot be Changed...
Страница 134: ...FST 500 Manual Page 134...
Страница 135: ...FST 500 Manual Page 135...
Страница 144: ...FST 500 Manual Page 144 EMI Filter RF022M21BA RF075M43BA EMI Filter 16TDT1W4S Used on 0 5 3 HP 230V Three Phase Models...
Страница 145: ...FST 500 Manual Page 145 EMI Filter 40TDS4W4B Used on 5 7 5 HP 230V Three Phase Models...