FST 500 Manual
- Page 23 -
Terminal symbols and functions
Terminal Symbol
Terminal Function
Factory Settings (NPN mode)
RA
Multi-Function Relay Output
(N.O.) a
RA-RC
Resistive Load
5A(N.O.)/3A(N.C.) 277Vac;
5A(N.O.)/3A(N.C.) 30Vdc
Refer to P45 for programming.
RB
Multi-Function Relay Output
(N.C.) b
RB-RC
Resistive Load
5A(N.O.)/3A(N.C.) 277Vac;
5A(N.O.)/3A(N.C.) 30Vdc
RC
Multi-function Relay Common
5A(N.O.)/3A(N.C.) 277Vac;
5A(N.O.)/3A(N.C.) 30Vdc
M0
Multi-function auxiliary input
M0~M5-GND
Refer to P38~P42 for programming the
multifunction inputs.
ON: the activation current is 10 mA.
OFF: leakage current tolerance is 10
μ
A.
M1
Multi-function input 1
M2
Multi-function input 2
M3
Multi-function input 3
M4
Multi-function input 4
M5
Multi-function input 5
GND
Common Signal
+10V
+10 Vdc Output
+10V-GND
It can 10 VDC power.
AVI
Analog Voltage Input
Impedance: 20k
Ω
Resolution: 10 bits
Range: 0~10Vdc = 0~Max.Output Frequency
ACI
Analog Current Input
Impedance: 250
Ω
Resolution: 10 bits
Range: 4~20mA = 0~Max.Output Frequency
Содержание FST-500 Series
Страница 8: ...FST 500 Manual Page 8 1 1 3 External Parts and Labels...
Страница 9: ...FST 500 Manual Page 9 1 1 4 Remove instructions...
Страница 17: ...FST 500 Manual Page 17...
Страница 22: ...FST 500 Manual Page 22 2 4 Control Terminal Wiring Factory Settings...
Страница 27: ...FST 500 Manual Page 27 3 1 2 How to Operate the Digital Keypad LC M02E...
Страница 28: ...FST 500 Manual Page 28 3 1 3 LC M02E Reference Table for the 7 segment LED Display of the Digital Keypad...
Страница 49: ...FST 500 Manual Page 49 Commonly used V F Setting 1 General Purpose...
Страница 87: ...FST 500 Manual Page 87 ASCII mode Command message Response message RTU mode Command message Response message...
Страница 110: ...FST 500 Manual Page 110 Chapter 5 Troubleshooting 5 1 Over Current OC...
Страница 111: ...FST 500 Manual Page 111 5 2 Ground Fault 5 3 Over Voltage OV...
Страница 112: ...FST 500 Manual Page 112 5 4 Low Voltage Lv...
Страница 113: ...FST 500 Manual Page 113 5 5 Over Heat OH1 5 6 Overload...
Страница 114: ...FST 500 Manual Page 114 5 7 Keypad Display is Abnormal 5 8 Phase Loss PHL...
Страница 115: ...FST 500 Manual Page 115 5 9 Motor cannot Run...
Страница 116: ...FST 500 Manual Page 116 5 10 Motor Speed cannot be Changed...
Страница 134: ...FST 500 Manual Page 134...
Страница 135: ...FST 500 Manual Page 135...
Страница 144: ...FST 500 Manual Page 144 EMI Filter RF022M21BA RF075M43BA EMI Filter 16TDT1W4S Used on 0 5 3 HP 230V Three Phase Models...
Страница 145: ...FST 500 Manual Page 145 EMI Filter 40TDS4W4B Used on 5 7 5 HP 230V Three Phase Models...