FST 500 Manual
- Page 122 -
Fault Name
Fault Descriptions
Corrective Actions
Auto accel / decel failure
Don‟t use the function of auto acceleration/
deceleration.
Ground fault :
The AC drive output is abnormal.
When the output terminal is
grounded (short circuit current is
50% more than the AC drive rated
current), the AC drive power
module may be damaged.
The short circuit protection is
provided for AC drive protection,
not user protection
Ground fault :
1. Check whether the IGBT power module is
damaged.
2. Check for possible poor insulation at the
output line.
Communication Error
Please refer to Pr.92.
1. Check the connection between the AC drive
and computer for loose wires.
2. Check if the communication protocol is
properly set.
External Base Block.
AC drive output is turned off.
1. When
the
external
input
terminal
(baseblock) is active, the AC drive output will
be turned off.
2. Disable this connection and the AC drive will
begin to work again.
OC hardware error
Return to the factory.
CC (current clamp)
OV hardware error
GFF hardware error
OV or LV
Current sensor error
U-phase error
Return to the factory.
W-phase error
Phase Loss
Check input phase wiring for loose contacts.
Software protection failure
Return to the factory.
PID feedback signal error
1. Check parameter settings (Pr.116) and
AVI/ACI wiring.
2. Check for possible fault between system
response time and the PID feedback signal
detection time (Pr.123)
Содержание FST-500 Series
Страница 8: ...FST 500 Manual Page 8 1 1 3 External Parts and Labels...
Страница 9: ...FST 500 Manual Page 9 1 1 4 Remove instructions...
Страница 17: ...FST 500 Manual Page 17...
Страница 22: ...FST 500 Manual Page 22 2 4 Control Terminal Wiring Factory Settings...
Страница 27: ...FST 500 Manual Page 27 3 1 2 How to Operate the Digital Keypad LC M02E...
Страница 28: ...FST 500 Manual Page 28 3 1 3 LC M02E Reference Table for the 7 segment LED Display of the Digital Keypad...
Страница 49: ...FST 500 Manual Page 49 Commonly used V F Setting 1 General Purpose...
Страница 87: ...FST 500 Manual Page 87 ASCII mode Command message Response message RTU mode Command message Response message...
Страница 110: ...FST 500 Manual Page 110 Chapter 5 Troubleshooting 5 1 Over Current OC...
Страница 111: ...FST 500 Manual Page 111 5 2 Ground Fault 5 3 Over Voltage OV...
Страница 112: ...FST 500 Manual Page 112 5 4 Low Voltage Lv...
Страница 113: ...FST 500 Manual Page 113 5 5 Over Heat OH1 5 6 Overload...
Страница 114: ...FST 500 Manual Page 114 5 7 Keypad Display is Abnormal 5 8 Phase Loss PHL...
Страница 115: ...FST 500 Manual Page 115 5 9 Motor cannot Run...
Страница 116: ...FST 500 Manual Page 116 5 10 Motor Speed cannot be Changed...
Страница 134: ...FST 500 Manual Page 134...
Страница 135: ...FST 500 Manual Page 135...
Страница 144: ...FST 500 Manual Page 144 EMI Filter RF022M21BA RF075M43BA EMI Filter 16TDT1W4S Used on 0 5 3 HP 230V Three Phase Models...
Страница 145: ...FST 500 Manual Page 145 EMI Filter 40TDS4W4B Used on 5 7 5 HP 230V Three Phase Models...