Averaging is another way to improve accuracy. The improvement is
proportional to the square root of the number of averages. The im-
provement from averaging, however, comes at the expense of increased
sweep time.
Figure 8-11 shows the measured reduction in noise due to bandwidth
and averaging.
Example: Using 1 kHz BW reduction and 10 averages, you would in-
crease the signal-to-noise ratio by 7.6 dB but would lengthen the time
required for the measurement by a factor of 4.3. This example as-
sumes a constant signal power.
LOW LEVEL AND GAIN
MEASUREMENTS
8-16
37XXXC OM
M E A S U R E M E N T S O N A 7 0 d B A T T E N U A T O R
A L L D A T A N O R M A L I Z E D T O
A 1 k H z I F B A N D W I D T H A N D 1 A V E R A G E
R E L A T I V E
N O I S E ( d B )
N U M B E R O F A V E R A G E S
7 . 0
3 . 5
1 . 4
. 3 5
. 1 4
1
2
5
1 0
2 0
5 0
1 0 0 2 0 0
5 0 0
1 0 K H z ( I F B W )
1 K H z
1 0 0 H z
. 7
Figure 8-11.
Reduction in Noise Using Averaging
AVERAGING
Up to 4096 Averages
Reduces Noise
Increases Sweep Time
Содержание 37 C Series
Страница 3: ......
Страница 4: ......
Страница 18: ...Figure 1 1 Model 37XXXC Vector Network Analyzer System...
Страница 32: ......
Страница 41: ......
Страница 61: ...Intentionally Blank...
Страница 96: ...Table of Contents 5 1 INTRODUCTION 5 3 5 2 ERROR MESSAGES 5 3 Chapter 5 Error and Status Messages...
Страница 97: ......
Страница 103: ......
Страница 117: ...HARD COPY AND DISK OUTPUT DATA DISPLAYS 6 16 37XXXC OM Figure 6 12 Example of a Tabular Printout 37347C...
Страница 223: ......
Страница 242: ...37XXXC OM 9 21 9 22 TIME DOMAIN MENU FLOWCHART Figure 9 25 Time Domain Menu Flow...
Страница 276: ......
Страница 323: ......
Страница 567: ......
Страница 582: ...37100C 37200C 37300C Vector Network Analyzers Technical Data Sheet Vector Network Analysis up to 65 GHz...