Amplifier Faults
ANILAM amplifiers do not require any scheduled maintenance, although it
is a good idea to occasionally check for dust build up or other
contamination.
If an amplifier should cease to operate or one or more of the fault Light
Emitting Diodes (LEDs) are lit, refer to
Table 9
.
NOTE:
A fault can on be caused by abnormal conditions. Locate and
correct the cause of the fault before repeated recycling of power
to the amplifier to prevent possible damage.
Table 9, Amplifier – LED Indicators
Red Green
Condition
Off Off No
power
Off On Enabled
On Off Fault
On On Inhibit
Miscellaneous Tests (F9)
Press
Misc
(
F9
) to display a pop-up menu with eight (8) selections. The
tests marked
**
on the right apply only for systems equipped with an
ANILAM AC Amplifier (P/N 33001279). These tests can only be activated
with the Servo Amplifier Test Board installed. See “Servo Amplifier Test
Board.” The pop-up does not display the
**
notation.
CanBus Test
Save Amp Settings
**
Amplifier Test Link
**
Reset Amplifier
**
BackUp Amp Settings
**
Restore from BackUp*
*