CNC Motion Setup/Testing Utility
P/N 70000634C
All rights reserved. Subject to change without notice.
November 2009
14
Table 5, Table of Fault LED Conditions (5 LEDs)
Input or Fault
Condition
RUN
LED
HS/ECB
LED
LS/ECB
LED
OVER VOLT
LED
OVER TEMP
LED
FAULT
OUTPUT
NORMAL
OPERATION
ON
OFF OFF OFF
OFF GROUND
LIMIT + (ON)
ON
OFF OFF OFF
OFF GROUND
LIMIT – (ON)
ON
OFF OFF OFF
OFF GROUND
CLAMP (ON)
OFF
OFF
OFF
OFF
OFF
GROUND
RESET (ON)
OFF
OFF
OFF
OFF
OFF
PULL-UP
EXT. FAULT
OFF
OFF
OFF
OFF
OFF
PULL-UP
UNDER VOLTAGE
(+15V)
OFF OFF OFF
OFF
OFF
PULL-UP
HS/ECB (LATCHED)
OFF
ON
OFF OFF
OFF
PULL-UP
LS/ECB (LATCHED)
OFF
OFF
ON
OFF OFF
PULL-UP
OVER VOLTAGE B+
(LATCHED)
OFF OFF OFF
ON
OFF
PULL-UP
OVER TEMP
(LATCHED)
OFF OFF OFF
OFF
ON PULL-UP
For LED fault conditions 1 LED servo amplifiers, see
Figure 9, ANILAM
Servo Amplifier (1 LED), P/N 33000123, DC Systems
or
Table 6
.
Table 6, Table of Fault LED Conditions (1 LED)
Green Red Condition
ON OFF
RUN
ON
2 FLASHES
+/– LIMITS
OFF OFF
AMPLIFIER
INHIBIT
OFF ON RESET
OFF
1 FLASH
OVER TEMPERATURE
OFF
2 FLASHES
OVER VOLTAGE
OFF 3
FLASHES
LS/ECB
OFF 4
FLASHES
HS/ECB