- 18 -
3269870_ut_GB_rev.2
ENGLISH
GB
TABLE OF ALARM INDICATIONS
Alarm
Causes
Remedy
E00
Safety thermostat failure.
The appliance’s functions are disabled so no cooking
cycles can be carried out. Reset the safety ther-
mostat; if the problem persists, call the after- sales
service
E01
Start the cooking well probe
(left well).
The appliance’s functions are disabled so no cooking
cycles can be carried out.
Importante
Important
Contact the after-sales service.
E.01
Start the cooking well probe
(left well).
The appliance’s functions are disabled so no cooking
cycles can be carried out.
Importante
Important
Contact the after-sales service.
E02
Start the cooking well probe
(right well).
The appliance’s functions are disabled so no cooking
cycles can be carried out.
Importante
Important
Contact the after-sales service.
E.02
Start the cooking well probe
(right well).
The appliance’s functions are disabled so no cooking
cycles can be carried out
Importante
Important
Contact the after-sales service.
E05
Electronic circuit board diag-
nostics tripped.
The appliance’s functions are disabled so no cooking
cycles can be carried out .
Importante
Important
Contact the after-sales service.
E06
Electronic circuit board diag-
nostics tripped.
The appliance’s functions are disabled so no cooking
cycles can be carried out.
Importante
Important
Contact the after-sales service.
E07
Electronic circuit board diag-
nostics tripped.
The appliance’s functions are disabled so no cooking
cycles can be carried out.
Importante
Important
Contact the after-sales service.