GB
- 14 -
3269870_inst_GB_rev.2
ENGLISH
ADJUSTING BURNER PRIMARY AIR
(0N1FR1ID-0T1FR1ID-1N1FR2ID-1T1FR2ID)
B
C
A
29±1mm
To carry out this operation, proceed as follows.
1)
Turn off the gas supply tap.
2)
Open the hatch
(A)
.
3)
Undo the locking screw
(B)
.
4)
Set the bush
(C)
at the distance as shown in
the fi gure.
5)
Tighten the screw
(B)
.
After making the setting, seal the screw with
paint.
6)
Close the hatch
(A)
when the operation is
complete.
REPLACING PARTS
INSTRUCTIONS AND WARNING FOR REPLACING PARTS
Importante
Important
Before carrying out any replacement procedure,
activate all the safety devices provided and de-
cide whether staff at work and those in the vicin-
ity should be informed. In particular, turn off the
gas supply tap, cut off the electricity supply us-
ing the master switch and prevent access to all
devices that might cause unexpected health and
safety hazards if turned on. If worn parts have to
be replaced, use original spare parts only.
The manufacturer declines all responsibly for
injury or damage to components due to the
use of non original parts, or extraordinary
work on the appliance which may modify the
safety requirements without the manufactur-
er’s authorisation.
When ordering components, follow the in-
structions provided in the parts catalogue.
REPLACEMENT OF THE BURNER NOZZLE
(0N1FR1ID-0T1FR1ID-1N1FR2ID-1T1FR2ID)
To carry out this operation, proceed as follows.
1)
Turn off the gas supply tap.
2)
Open the hatch
(A)
.
3)
Unscrew the nozzle
(B)
and replace it with
the one suitable for the type of gas in use (see
table at back of manual).
4)
Close the hatch
(A)
.
A
B
B
Содержание 0N1FR1ID
Страница 102: ......
Страница 104: ......
Страница 137: ......
Страница 142: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM 1N1FR2ID 1T1FR2ID 1 3 2 2 5 6 6 7 7 8 4 9 10 11 12 13 230V1N 220V1N V ...
Страница 153: ......