Page 71
AD-4401A
FncF-
Item
Setting Value
Default
04
Function of sub-display
0: None
1: Gross value
2: Net value
3: Tare value
4: Final weight
5: Total weight
6: Number of accumulations
7: Weighing sequence error
0
05
Condition to turn the FUNCTION
status ON
0: None
1: During discharge
2: When zero tracking is enabled
3: In weighing sequence
4: Normal batching ( /loss-in-weight
batching)
2
10
1
digit: Pre-digital filter cutoff
frequency
10
0
digit:
Post-digital filter cutoff
frequency
Pre-digital filter and post-digital filter
are connected in series.
0: None
1: 11.0 Hz
2: 8.0 Hz
3: 5.6 Hz
4: 4.0 Hz
5: 2.8 Hz
6: 2.0 Hz
7: 1.4 Hz
8: 1.0 Hz
9: 0.7 Hz
06
HPDF cutoff frequency
101: 11.0 Hz (HPDF)
102: 8.0 Hz (HPDF)
103: 5.6 Hz (HPDF)
104: 4.0 Hz (HPDF)
105: 2.8 Hz (HPDF)
106: 2.0 Hz (HPDF)
107: 1.4 Hz (HPDF)
108: 1.0 Hz (HPDF)
109: 0.7 Hz (HPDF)