AD-4401A Page
52
●
Data format (Setpoint values)
Setpoint data format depends on the weighing mode (CALF-14).
Normal batching / Simple comparison normal batching: (CALF-14 1, 3)
Final
weight
Free
fall
Preliminary Optional
preliminary
Overweight
Underweight Near-
zero
Terminator
6 chars 6 chars 6 chars
6 chars
6 chars
6 chars
6 chars
2 chars
/1char
Loss-in-weight batching / Simple comparison loss-in-weight batching: (CALF-14 2, 4)
Final
weight
Free
fall
Preliminary Full
Overweight
Underweight Near-
zero
Terminator
6 chars 6 chars 6 chars
6 chars
6 chars
6 chars
6 chars
2 chars
/1char
Check weighing 1/2/3/4: (CALF-14 5, 6, 7, 8)
Target
weight
Hi-Hi limit
Hi limit
Lo limit
Lo-Lo limit
-
Near-
zero
Terminator
6 chars 6 chars
6 chars
6 chars
6 chars
6 chars
6 chars
2 chars
/1char
Item
Value (e.g. Unit = kg, Decimal point position = 0.000)
Final weight/Target
0 2 0 0 0 0 20.000
kg
Free fall/Hi-Hi limit
0 0 0 1 0 0 0.100
kg
Preliminary/Hi limit
0 0 2 0 0 0 0.2000
kg
Optional preliminary/Full/Lo limit
0 1 8 0 0 0 18.000
kg
Overweight/Lo-Lo limit
0 0 0 0 2 0 0.0020
kg
Underweight 0 0 0 0 2 0 0.0020
kg
Near-zero 0 0 0 2 0 0 0.0200
kg