Page 21
AD-4401A
Timing chart
Final weight
Free
fall
Underweight
Overweight
Preliminary
Medium flow output
Small flow output
Weighing start input
Weighing end output
OK/Over/Under output
T1
T2
T3
T4
T5
Judge
T1: Weighing start input delay time
T2: Medium flow comparison disable time
T3: Small flow comparison disable time
T4: Judging delay time
T5: Weighing end output time