![Analog Devices ADIS1700 Series Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752097.webp)
Table 7-120:
Self Test Command - Header
Field Name
Type
Value
Module ID
U1
0x10
Reserved1
U1
0
Command ID
U2
0x80
Version
U4
1
Reserved2
U4
0
Payload Size
U4
4 x N
Table 7-121:
Self Test Command - Payload
Field Name
Type
Value
Notes
Test Count
U4
N
N
≤
8
x N
Test ID
U1
1 - 10
Same test ID can be specified multiple
times but is executed only once
Table 7-122:
Self Test Response- Header
Field Name
Type
Value
Notes
Module ID
U1
0x10
Reserved1
U1
0
Command ID
U2
0x80
Version
U4
1
Reserved2
U4
0
Payload Size
U4
4 + 4N
Result Status
U4
0 – all the tests passed
0x20 – one of the tests failed
Table 7-123:
Self Test Response - Payload
Field Name
Type
Value
Notes
Test Count
U4
N
x N
Test ID
U1
Test Re-
sult
U1
0xFF – test not available
Result
Value
U2
Camera Module Messages
7–48
ADIS1700x Vision-Sensing Camera Module User Guide