![Analog Devices ADIS1700 Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752091.webp)
Table 7-106:
Set Luminance Image Response - Header (Continued)
Field Name
Type
Notes
Result Status
U4
0x20 – Invalid image size. (The image size must
match the image size expected by the application).
If this is not the case, the device flags the error and
ignores the message content.
0x30 – Unexpected chunk index. (This error is
caused by a missing index). A chunk index of 0 in-
dicates that the host wants to restart the image up-
loading. This operation is valid and no error is
flagged.
Get ADVS200x Tuning Parameters
This command is sent to read the values of ADVS200x imager parameters. The IDs of the parameters to be read are
sent in the command payload. The command and response payloads have a similar structure.
C++ API:
void SnapSensor::SensorConnection::CameraModule:: GetADVS200xParameters
(IADVS200xRegisters *dstADVS200xRegisters, IADVS200xLut *dstADVS200xLut)
Table 7-107:
Get Tuning Parameters Command - Header
Field Name
Type
Value
Module ID
U1
0x10
Reserved1
U1
0
Command ID
U2
0x20
Version
U4
1
Reserved2
U4
0
Payload Size
U4
4 + 8N
Reserved3
U4
Table 7-108:
Get Tuning Parameters Command - Payload
Field Name
Type
Value
Notes
Num of Parameters
U4
N
x N
Param ID
U4
N is the number of parameters to read.
The parameter value is disregarded. The parame-
ter ID contains the ID of the parameters to read.
The last parameter ID is the null parameter (Pa-
rameter ID = 0xFFFF) which is used as a termina-
tor.
Value
U4
Camera Module Messages
7–42
ADIS1700x Vision-Sensing Camera Module User Guide