Get Log Data Summary
This command requests the summary of the data currently logged on the device whose sequence ID is greater or
equal than the command parameter “start index”. The data returned are (the following data are computed by the
device by taking into account only logged items with sequence ID greater than the command parameter start index):
•
Start Index : the first valid logged item sequence ID greater than the command parameter start index
•
Total Logged Items
•
Space Left : space left in bytes (zero after the first data logging buffer rollover)
•
Logged Types Count: count of how many types of logged items are currently logged.
•
Count of logged items for each type.
Table 7-164:
Get Log Data Summary Command - Header
Field Name
Type
Notes
Module ID
U1
0x40
Reserved1
U1
0
Command ID
U2
0x31
Version
U4
1
Reserved2
U4
0
Payload Size
U4
4
Result Status
U4
0
Table 7-165:
Get Log Data Summary Command - Payload
Field Name
Type
Notes
Start Index
U4
Table 7-166:
Get Log Data Summary Response - Payload
Field Name
Type
Notes
Module ID
U1
0x40
Reserved1
U1
0
Command ID
U2
0x31
Version
U4
1
Reserved2
U4
0
Payload Size
U4
16 + N × 4
Result Status
U4
0
Storage Module Messages