![Analog Devices ADIS1700 Series Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752067.webp)
Table 7-38:
Validate Section Command - Payload (Continued)
Field Name
Type
Notes
Content Version
U4
CRC
U4
Table 7-39:
Validate Section Response- Header
Field Name
Type
Notes
Module ID
U1
1
Reserved1
U1
NV storage medium ID
Command ID
U2
0x24
Version
U4
1
Reserved2
U4
0
Payload Size
U4
4
Result Status
U4
0
Table 7-40:
Validate Section Response - Payload
Field Name
Type
Notes
Computed CRC
U4
Create/Recover Restore Point
A restore point consists of a “code plus data” bundle; an application code plus its initialization data.
The application can have one or more restore points (only one in the current implementation). When only one re-
store point is available, create a restore point of the factory configuration (application code and initialization data
saved during production). When the product must be commissioned, create a restore point after commissioning.
The benefit of the restore point is to create the possibility, at any time, to revert to a previous software / configura-
tion when either the update or the initialization data modification failed.
C++ API:
void
SnapSensor::SensorConnection::ApplicationModule::CreateRestorePoint(
unsigned int RestorePointID)
void
SnapSensor::SensorConnection::ApplicationModule::RecoverRestorePoint(
unsigned int RestorePointID)
Bootloader Messages
7–18