Table 7-69:
Get LED Mode Response - Header
Field Name
Type
Notes
Module ID
U1
1
Reserved1
U1
0
Command ID
U2
0x60
Version
U4
1
Reserved2
U4
0
Payload Size
U4
2 + 2 × N
Result Status
U4
0x40 – Invalid LED ID
Table 7-70:
Get LED Mode Response - Payload
Field Name
Type
Notes
Num LEDs
U2
N = 1– 32
N× LED
ID
U1
0 – 255
Mode
U1
Bits 0 (LSB) to 2 are for the mode
0 : Nominal (fixed light) when on
1 : Blinking when on
2 : Always off (override )
3 : Always on (override)
4 : Always blinking (override)
Bit 6 – Led state is on
Bit 7 (MSB) – Led light on/blinks
Table 7-71:
LED ID Description
LED Name
ID
Notes
Status LEDs
0
Set LED Mode
The Set LED command sets the mode of the board LEDs. Several different modes can be configured. Multiple
LEDs can be configured with one single message. See the
The device firmware sets LEDs to on or off by switching the LED state. The host can read bit 6 of the
Mode
field
in the Get LEDs Mode response to know the current LED state. But, the host cannot change the bit. The host can
change the LED light state by overriding the LED state using modes 2 to 4.
When the mode is nominal fixed or nominal blinking, the LED light state is equal to the LED state (the LED is
driven by the device).
Main Application Messages
7–30