Appendix C: Using an IRIS IR Capture Unit
198
VisualArchitect v1.1
CONFIDENTIAL AND PROPRIETARY. COPYRIGHT, AMX LLC, 2006
IRIS - Display Characters and P Mode Settings
The following table lists the display characters and P mode settings for special remote controllers (RCs).
IRIS - Baud Rate Settings
The default communication setting for the IRIS unit is 9600 baud. You can change the baud rate with the
up, down, and send pushbuttons.
You must set the IRIS unit's baud rate to match the baud rate of the PC running Visual Architect to store
RC functions.
To set the baud rate:
1.
Disconnect the power supply from the IRIS unit.
2.
Press and hold the up, down, and send pushbuttons. Reconnect the power supply and release the
pushbuttons.
Default Mode Settings:
• Default
Setting
• Baud
9600
• P3
off
• P4
on
• P5
off
• P6
on
• P7
on
• P8
off
Display Characters and P Mode Settings
Characters Description
• [ ]
RC function is captured, analyzed, stored, and verified.
• Er
Error: RC function did not verify correctly.
• Nd
No Device. Communication device error detected, or the IRLIB program is not staged to
receive RC functions.
• NO
Normal Operation. Ready to capture RC.
• OF
P mode is off.
• On
P mode is on.
• So
Send OK. RC function sent without errors to a PC running IRLIB.
• SP
Special Function. Special mode to capture unusual RC functions.
• P1-P2
Not used.
• P3
Sends RC functions to a PC running IRLIB automatically after the VERIFY operation.
• P4
Disables the VERIFY operation to capture RC functions. Default mode requires the VERIFY
operation.
• P5
Loose-timing mode to capture JVC (PQ10956) RC functions.
• P6
Glitch-detection mode to capture Kinderman and some Mitsubishi RC functions.
• P7
Disables glitch-detection mode to capture non-carrier RC functions.
• P8
Strict-timing mode
The IRIS unit automatically sets the baud rate to 9600 when you connect power. If
you reset the baud to any other setting and disconnect power, the previous baud rate
setting is lost and the IRIS unit will default back to 9600 baud.
Содержание VISUALARCHITECT 1.1
Страница 12: ...x VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 Table of Contents ...
Страница 26: ...VisualArchitect v1 1 Overview 14 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 36: ...Creating a New VA Project 24 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 102: ...Setting Device Properties 90 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 106: ...Defining Control Strings 94 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 158: ...Finishing the Project 146 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 214: ...Appendix D AMX Icon 2 Character Map 202 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 240: ...Appendix F The InConcert Resource Center 228 VisualArchitect v1 1 CONFIDENTIAL AND PROPRIETARY COPYRIGHT AMX LLC 2006 ...
Страница 241: ...229 VisualArchitect v1 1 ...