VNC Send Commands
VNC is handled via an external application and is displayed in a window. To enable a VNC connection to a remote
device, a VNC App window must be created in the TPD project.
A single window can support connections to multiple destinations, though not simultaneously. Once a window is open,
the parameters such as host, username, and password can be changed via send commands.
The following send commands are available to control VNC sessions. The application window name (from TPDesign5)
is used as the key to update VNC parameters. If an existing window is open, the session should be logged out first before
changing any parameters to avoid undefined behavior. Once all the parameters have been changed, then login to connect
with the new parameters.
SIP Setup Commands (Cont.)
^PHN-SETUP-PORT
Sets the port number for the proxy server.
Syntax:
"'^PHN-SETUP-PORT,<port>'"
Variable:
port = The port for the proxy server
Example:
SEND_COMMAND Panel,"'^PHN-SETUP-PORT,5060'"
^PHN-SETUP-PROXYADDR
Sets the IP address for the proxy server.
Syntax:
"'^PHN-SETUP-PROXYADDR,<IP>'"
Variable:
IP = The IP address for the proxy server
Example:
SEND_COMMAND Panel,"'^PHN-SETUP-PROXYADDR,192.168.223.111'"
^PHN-SETUP-USERNAME
Sets the user name for authentication with the proxy server.
Syntax:
"'^PHN-SETUP-USERNAME,<username>'"
Variable:
username = The user name (usually the phone extension)
Example:
SEND_COMMAND Panel,"'^PHN-SETUP-USERNAME,6003'"
VNC Send Commands
^BVL
Login to VNC Session.
Syntax:
^BVL-appWindowName,<1=Logon|0=Logoff>
Login/out of an existing session.
For logon, if the window is not open, the window is opened and the session is connected using the current
parameters. If the window is already open, then the session is updated to new/current parameters.
Logoff will close the session and window.
^BVG
Update parameter list.
Syntax:
^BVG-appWindowName,paramList
This command is a generic form of the remainder of the commands. Any parameter in the VNC App Parameter
List from TPDesign can be updated with this command by including the KEV pair in the list.
For instance, the password can be changed:
^BVG-VNCClient,password=myNewPassword
One limitation is that no commas may be used in any of the fields.
Delimiters are not escaped at this time.
Содержание Modero G5
Страница 58: ...Settings Menu 48 Modero G5 Touch Panels Configuration and Programming ...
Страница 62: ...Gestures 52 Modero G5 Touch Panels Configuration and Programming ...
Страница 66: ...MXA MP and MXA MPL Programming 56 Modero G5 Touch Panels Configuration and Programming ...
Страница 138: ...Appendix B Bargraph Functions 128 Modero G5 Touch Panels Configuration and Programming ...
Страница 143: ...Appendix C Video Streaming Troubleshooting 133 Modero G5 Touch Panels Configuration and Programming ...