OPERATION INSTRUCTIONS
P
ROCESS
M
ANUAL
5.7 Edit ‘Variable Process Command’
‘Variable Process Command‘ can be used to quickly modify specific process settings. Only
those lines in the process recipe that have been assigned as ‘Variable Commands‘ will be
presented in a list. From this list the desired process setting may be modified.
‘Variable Process Command‘ can be set at all times until the recipe step is executed in which
the specific ‘Variable Command‘ is programmed.
5.7.1
Touchscreen
1) return to the Main Menu by
pressing ‘ESC’ until the following
screen appears:
2) press ‘4’ to access ‘Tube Control’
3) press ‘5’ to access ‘Variable
Commands’
4) edit the desired process setting
1) enter
the
corresponding line
number
2) modify to the
desired setting
3)
press ‘Return’ to
confirm the
modification
5)
repeat step 4) until all desired
process settings have been
set
6) Press ‘Esc’ to store the new
commands. The message
‘Process recipe variable
5.7-1