Chapter Three : AMIBIOS Setup
79
Section 2
Advanced Setup,
Continued
Parallel Port Address
This option specifies the I/O address used by the parallel port. The Optimal setting is
378
.
The Fail-Safe setting is
Disabled
.
Option Description
Disabled
This option prevents the parallel port from accessing any system resources. It is not made
available.
378
This option allows the serial port to use 378 as its I/O port address. This is the default setting.
The majority of parallel ports on computer systems use IRQ7 and I/O Port 378H as the standard
setting.
278
This option allows the serial port to use 278 as its I/O port address.
3BC
This option allows the serial port to use 3BC as its I/O port address.
Parallel Port Mode
This option specifies the parallel port mode. The Optimal setting is
Normal
. The Fail-
Safe setting is
Disabled
.
Option Description
Normal
This option allows the standard parallel port mode to be used. This is the default setting.
Bi-Directional
This option allows data to be sent to and received from the parallel port.
EPP
The parallel port can be used with devices that adhere to the Enhanced Parallel Port (EPP)
specification. EPP uses the existing parallel port signals to provide asymmetric bi-directional
data transfer driven by the host device.
When EPP is selected, you can select the EPP Version as either 1.7 or 1.9.
ECP
The parallel port can be used with devices that adhere to the Extended Capabilities Port (ECP)
specification. ECP uses the DMA protocol to achieve data transfer rates up to 2.5 Megabits per
second. ECP provides symmetric bi-directional communication.
When ECP is selected, you can change the value of the ECP Mode DMA Channel. It can be set
to 0, 1, or 3.
Parallel Port IRQ
This option specifies the IRQ used by the parallel port. The Optimal and Fail-Safe
default setting is
7
.
Option Description
5
This option allows the serial port to use Interrupt 3.
7
This option allows the serial port to use Interrupt 7. This is the default setting. The majority of
parallel ports on computer systems use IRQ7 and I/O Port 378H as the standard setting.
Cont’d
Содержание Olympus III
Страница 1: ...Olympus III User s Guide MAN 875 02 02 04...
Страница 14: ...American Megatrends Inc Olympus III User s Guide Series 875 4 Rear I O Ports...
Страница 20: ...American Megatrends Inc Olympus III User s Guide Series 875 10...
Страница 138: ...American Megatrends Inc Olympus III User s Guide Series 875 128...
Страница 140: ...American Megatrends Inc Olympus III User s Guide Series 875 130...