113406-1
www.amdry.com
3
7. A program
should be
established for the inspection and cleaning of lint in the burner area, exhaust ductwork,
and area around the back of the dryer. The frequency of inspection and cleaning can best be determined
from experience at each location.
WARNING:
The collection of lint in the burner area and exhaust ductwork can create a potential fire
hazard.
8. For personal safety, the dryer
must be
electrically grounded in accordance with local codes and/or the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE:
Failure to electrically ground the dryer properly will VOID THE WARRANTY.
9.
UNDER
NO
CIRCUMSTANCES
should the dryer door switch, the lint drawer switch, or the heat
safety circuit ever be disabled.
WARNING: PERSONAL INJURY OR FIRE COULD RESULT SHOULD THE DRYER
DOOR SWITCH, THE LINT DRAWER SWITCH, OR THE HEAT SAFETY
CIRCUIT EVER BE DISABLED.
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING:
Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
12.
DO NOT
operate steam dryers with more than 125 psi (8.62 bar) steam pressure. Excessive steam
pressure can damage the steam coil and/or harm personnel.
13. Replace leaking flexible steam hoses or other fixtures immediately.
DO NOT
operate the dryer with
leaking flexible hoses.
PERSONAL INJURY MAY RESULT.
14. READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE DRYER.
15. For safety, proper operation, and optimum performance, the dryer
must not be
operated with a load less
than sixty-six percent (66%), 112 lbs (51 kg) of its rated capacity.
WARNING: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND
THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS
FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY
EQUIPMENT PER OSHA
(Occupational Safety and Health Administration)
STANDARDS.
IMPORTANT: Dryer must be installed in a location/environment, which the ambient
temperature remains between 40° F (4.44° C) and 130° F (54.44° C)
.
Содержание ML-175